What is the maximum allowable height above the finished floor for operable hardware?

What is the maximum allowable height above the finished floor for operable hardware?

between 34 inches and 48 inches
Generally, hardware must be mounted between 34 inches and 48 inches above the finished floor or ground, with exceptions for (a) locks used only for security purposes, and (b) operable hardware on doors leading to swimming pools.

How high should a storm door handle be?

What does the ADA have to say about door handle height? Fortunately, the standards for ADA door handle height are not much different than traditional recommendations. All handles, pulls, latches, locks, and other operable parts of the door should measure between 34 inches and 48 inches above the floor.

Where are panic hardware required?

The required locations for panic hardware vary depending on which code has been adopted, but typically, panic hardware is required for assembly, educational/daycare, and high hazard occupancies, where the calculated occupant load is 50 people or more (International Building Code (IBC) and International Fire Code (IFC …

What is ADA height for push pull plates?

48 in.
Hardware required for accessible door passage shall be mounted no higher than 48 in. (1220 mm) above finished floor.

What is code for door handle height?

Door handles, pulls, latches, locks and other operating devices shall be installed 34 inches (864 mm) minimum and 48 inches (1219 mm) maximum above the finished floor. Locks used only for security purposes and not used for normal operation are permitted at any height.

Should storm door handle be on same side as main door handle?

When installing a storm door, the storm door handle and the entry door handle are located on the same side. If the jamb depth measurements are less than those required to properly mount your storm door, then the storm door handle may interfere with the entry door handle.

What is the maximum height of an accessible door threshold?

The ADA requirements for thresholds are: Thresholds, if provided at a doorway, must not exceed 3/4 inch in height for exterior sliding doors or 1/2 inch for other types of doors. Changes in level up to 1/4 inch can be vertical and do not need an edge treatment.

What makes a pull ADA compliant?

Drawer pulls should be at a height accessible to a person in a wheelchair. In general, this means no higher than 48 inches or lower than 15 inches from the ground. If the person must reach over something that obstructs clear access to the drawer pull, the maximum height should be 44 inches.

How far does a door handle stick out?

Bring Out the Tape Measure This distance, known as the backset, typically equals 2-3/8 inches or 2-3/4 inches. Many replacement doorknobs will work with either backset, but be sure your new knob is designed to work with your measurement.

Related Posts